Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns.
dc.contributor.author | Xavier, Ellen Martins | |
dc.contributor.author | Ribeiro Neto, Juliano Geraldo | |
dc.contributor.author | Sarmanho, Arlene Maria Cunha | |
dc.contributor.author | Amparo, Lucas Roquete | |
dc.contributor.author | Paula, Letícia Gualberto Caldeira de | |
dc.date.accessioned | 2020-06-25T15:44:39Z | |
dc.date.available | 2020-06-25T15:44:39Z | |
dc.date.issued | 2019 | |
dc.description.abstract | This paper presents experimental and theoretical analysis of bolts employed as shear connectors in circular concrete-filled steel tube columns (CFTs). The theoretical results, obtained from ABNT NBR 16239:2013 formulations, were compared with the experimental results. A series of push-out tests were carried out, where the diameter and length of the bolts, the number of connectors and the concrete strength were varied. From the experimental results, it was observed that the equations from ABNT NBR 16239:2013 are conservative. Therefore, it is proposed an adjustment to the formulations in order to consider the concrete confinement. It was also verified that increments in the diameter and the length of the bolt increase the load capacity of the connector. However, the variation of the quantity of bolts and the concrete strength did not interfere in the load capacity. | pt_BR |
dc.description.abstracten | Este estudo apresenta análises experimentais e teóricas do uso de parafusos como conectores de cisalhamento em pilares mistos de aço em seção tubular circular preenchidos com concreto (PMPCs). Os resultados obtidos experimentalmente são comparados com os resultados das formulações propostas pela norma ABNT NBR 16239:2013. Os ensaios são de cisalhamento direto, variando parâmetros como diâmetro e comprimento dos parafusos, quantidade de conectores e resistência do concreto. A partir dos resultados experimentais observou-se que as equações da ABNT NBR 16239:2013 estão a favor da segurança, e é proposta uma adequação das formulações da norma para considerar o efeito do confinamento do concreto. Verificou-se também que o aumento do diâmetro e comprimento do parafuso aumenta a capacidade de carga do conector, porém a variação da quantidade de parafusos e da resistência do concreto não interferem na sua capacidade de carga. | pt_BR |
dc.identifier.citation | XAVIER, E. M. et al. Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns. Revista IBRACON de Estruturas e Materiais, São Paulo, v. 12, n. 2, p. 337-370, abr. 2019. Disponível em: <http://www.scielo.br/scielo.php?pid=S1983-41952019000200337&script=sci_arttext>. Acesso em: 10 mar. 2020. | pt_BR |
dc.identifier.doi | https://doi.org/10.1590/s1983-41952019000200008 | pt_BR |
dc.identifier.issn | 1983-4195 | |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/12388 | |
dc.language.iso | en_US | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | This is an open-access article distributed under the terms of the Creative Commons Attribution License. Fonte: o próprio artigo. | pt_BR |
dc.subject | Circular tubular section | pt_BR |
dc.subject | Seção tubular circular | pt_BR |
dc.title | Experimental analysis of bolts employed as shear connectors in circular concrete-filled tube columns. | pt_BR |
dc.title.alternative | Análise experimental do uso de parafusos como conectores de cisalhamento em pilar misto circular preenchido com concreto. | pt_BR |
dc.type | Artigo publicado em periodico | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- ARTIGO_ExperimentalAnalysisBolts.pdf
- Tamanho:
- 1.94 MB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- license.txt
- Tamanho:
- 924 B
- Formato:
- Item-specific license agreed upon to submission
- Descrição: