Desenvolvimento de métodos baseados na extração com partição à baixa temperatura para determinação simultânea de antibióticos em matrizes de estações de tratamento de esgoto por HPLC-MS/MS.

dc.contributor.advisorAfonso, Robson José de Cássia Francopt_BR
dc.contributor.advisorSanson, Ananda Limapt_BR
dc.contributor.authorCunha, Camila Cristina Rodrigues Ferreira da
dc.contributor.refereeAfonso, Robson José de Cássia Francopt_BR
dc.contributor.refereeQueiroz, Maria Eliana Lopes Ribeiro dept_BR
dc.contributor.refereeBrandt, Emanuel Manfred Freirept_BR
dc.contributor.refereeFaria, Adriana Ferreirapt_BR
dc.contributor.refereeAquino, Sergio Francisco dept_BR
dc.contributor.refereeBaeta, Bruno Eduardo Lobopt_BR
dc.date.accessioned2023-08-25T19:58:43Z
dc.date.available2023-08-25T19:58:43Z
dc.date.issued2021pt_BR
dc.descriptionPrograma de Pós-Graduação Multicêntrico em Química de Minas Gerais. Departamento de Química, Instituto de Ciências Exatas e Biológicas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractA ocorrência de antibióticos em matrizes ambientais constitui uma potencial ameaça à saúde pública, uma vez que contribui para a o desenvolvimento e disseminação da resistência bacteriana. Dessa forma, a determinação do nível de contaminação dos antibióticos e seu lançamento no meio ambiente, particularmente pelos sistemas de tratamento de esgotos, são de fundamental importância para apoiar estudos de investigação do perfil de resistência bacteriana. Neste trabalho, métodos analíticos foram desenvolvidos e validados baseados na extração por partição em baixa temperatura (LTPE) seguida por cromatografia líquida de alta eficiência acoplada à espectrometria de massas (HPLC-MS/MS) para a determinação multiclasse de antibióticos em matrizes complexas de estação de tratamento de esgoto (ETE), o qual inclui o esgoto bruto, tratado e o lodo anaeróbio. Os antibióticos analisados no esgoto foram: amoxicilina, cefalexina, sulfametoxazol, sulfadiazina, trimetoprima, ciprofloxacina, norfloxacina, levofloxacina e eritromicina, enquanto que para a matriz de lodo de esgoto foram: sulfametoxazol, sulfadiazina e trimetoprima. A quantificação dos antibióticos foi realizada pelo método da dupla injeção consecutiva, sem o uso de calibração interna com compostos marcados, a fim de corrigir os efeitos de matriz. Para a matriz de esgoto, os parâmetros avaliados e otimizados na LTPE foram: pH da amostra, razão volumétrica entre amostra e o solvente extrator, tempo de extração em banho ultrassônico, material do tubo de extração, solvente e volume para reconstituir os extratos da amostra. Adicionalmente, a influência dos sólidos presentes na matriz de esgoto foi avaliada. Amostras de esgoto na sua forma integral, incluindo as frações líquidas e sólidas do esgoto foram analisadas. Os resultados revelaram que a etapa de filtração, usualmente utilizada em várias técnicas de extração de analitos em amostras ambientais complexas, pode subestimar a concentração total de antibióticos presentes, principalmente, para os compostos hidrofóbicos que possuem maior afinidade pelos sólidos. O limite de detecção do método variou de 18,54 ng L-1 (trimetoprima) à 78,49 ng L-1 (ciprofloxacina), exceto para a amoxicilina que apresentou um limite de detecção maior (235,80 ng L-1 ). Precisão intradia (coeficiente de variação) menor do que 12,3% foi alcançada. Os valores de recuperação variaram de 13,9 (sulfadiazina) à 48,9% (eritromicina) nas amostras de esgoto bruto e de 19,1% (sulfadiazina) a 57,2% (ciprofloxacina) nas amostras de esgoto tratado. Na matriz de lodo de esgoto, avaliou-se a influência das seguintes variáveis no procedimento de extração: massa seca (ms) de lodo de esgoto, tempo de extração em banho ultrassônico, pH da solução tampão e número de ciclos de extração. Os limites de detecção do método variaram de 3,66 ng g-1 ms (trimetoprima) à 11,37 ng g-1 ms (sulfametoxazol). A precisão intradia alcançada foi menor do que 18,9%. Os valores de recuperação variaram de 29,1% (sulfadiazina) à 70,6% (trimetoprima). Os métodos desenvolvidos e validados foram aplicados para a determinação multirresíduo de antibióticos em esgoto bruto, tratado e lodo de esgoto. Seis dos nove antibióticos investigados foram detectados no esgoto bruto e cinco foram encontrados no esgoto tratado. Já no lodo de esgoto, apenas a trimetoprima foi detectada. O trabalho fornece uma nova compreensão sobre a aplicabilidade de LTPE para extração de resíduos de antibióticos de esgoto e lodo de esgoto.pt_BR
dc.description.abstractenThe occurrence of antibiotics in environmental matrices is a potential threat to public health, since it contributes to the development and spread of bacterial resistance. Thus, the determination of the antibiotic contamination level and their release into the environment, particularly by wastewater treatment systems, are fundamentally important to support the studies of bacterial resistance profile. In this study, analytical methods based on low- temperature partitioning extraction (LTPE) followed by high performance liquid chromatography coupled to mass spectrometry (HPLC-MS/MS) for the multiclass determination of antibiotics in complex matrices of wastewater treatment plant (WWTP), which includes raw sewage, treated sewage and anaerobic sludge, were developed and validated. The target antibiotics analyzed in sewage were: amoxicillin, cephalexin, sulfamethoxazole, sulfadiazine, trimethoprim, ciprofloxacin, norfloxacin, levofloxacin and erythromycin, while for the sewage sludge matrix were: sulfamethoxazole, sulfadiazine and trimethoprim. Quantification of antibiotics was performed by double consecutive injection method, without the use of a labeled compound, in order to correct matrix effects. For the sewage matrix, the parameters evaluated in the LTPE were: sample pH, volumetric ratio between sample and extracting solvent, extraction time in an ultrasonic bath, extraction tube material, solvente, and volume to reconstitute the sample extracts. Additionally, the influence of solids present in the sewage was evaluated. Sewage samples in their complete state were analyzed, including liquid and solid fractions of sewage. The results revealed that the filtration step, usually used in several analyte extraction techniques in complex environmental samples, can underestimate the total concentration of antibiotics present, particularly to the hydrophobic compounds that have higher affinity for solids. The method detection limit ranged from 18.54 ng L-1 (trimethoprim) to 78.49 ng L-1 (ciprofloxacin), except amoxicillin which showed a higher limit (235.80 ng L- 1). Intraday precision (relative standard deviation) of less than 12.3% was achieved. The recovery values ranged from 13.9% (sulfadiazine) to 48.9% (erythromycin) in influent samples and from 19.1% (sulfadiazine) to 57.2% (ciprofloxacin) in effluent samples. In the sewage sludge matrix, the influence of the following variables on the extraction procedure was evaluated: sewage sludge dry weight (dw), extraction time in an ultrasonic bath, pH of the buffer solution and number of extraction cycles. The method detection limits ranged from 3.66 ng g-1d.w. (trimethoprim) at 11.37 ng g-1dw (sulfamethoxazole). Intraday precision of less than 18,9% (RSD) was achieved. Recovery values ranged from 29.1% (sulfadiazine) to 70.6% (trimethoprim). The developed and validated methods were applied for the multiresidue determination of antibiotics in raw sewage, treated sewage, and sewage sludge. Six of the eight antibiotics investigated were detected in raw sewage whereas five were found in treated sewage. In the sewage sludge, only trimethoprim was detected. This work provides new insights on the applicability of LTPE for antibiotic residues extraction from sewage and sludge sewage.pt_BR
dc.identifier.citationCUNHA, Camila Cristina Rodrigues Ferreira da. Desenvolvimento de métodos baseados na extração com partição à baixa temperatura para determinação simultânea de antibióticos em matrizes de estações de tratamento de esgoto por HPLC-MS/MS. 2021. 188 f. Tese (Doutorado em Química) - Instituto de Ciências Exatas e Biológicas, Universidade Federal de Ouro Preto, Ouro Preto, 2021.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/17352
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 02/06/2022 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais.pt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectAntibióticospt_BR
dc.subjectResistência bacterianapt_BR
dc.subjectExtração com partição a baixa temperatura - LTPEpt_BR
dc.subjectEsgoto brutopt_BR
dc.titleDesenvolvimento de métodos baseados na extração com partição à baixa temperatura para determinação simultânea de antibióticos em matrizes de estações de tratamento de esgoto por HPLC-MS/MS.pt_BR
dc.typeTesept_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
TESE_DesenvolvimentoMétodosBaseados.pdf
Tamanho:
2.7 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: