Resistance factor calibration for perforated cold-formed steel compression members.

dc.contributor.authorJardim, Roberta Layra Faragó
dc.contributor.authorFreitas, Marcílio Sousa da Rocha
dc.contributor.authorBrandão, André Luis Riqueira
dc.date.accessioned2023-07-19T19:15:20Z
dc.date.available2023-07-19T19:15:20Z
dc.date.issued2022pt_BR
dc.description.abstractCold-formed Steel profiles are structural profiles widely used in civil construction. They are often manufactured with perforations. The designing can be performed using the direct resistance method. Formulations were adapted by Moen and Schafer (2008) to consider the presence of perforations in these profiles. The objective of this study is to investigate the structural safety of columns with web perforations. The calculation of the resistance capacity was performed using the formulations proposed by the authors. The reliability indexes were determined using the First Order Reliability Method (FORM), First Order Second Moment (FOSM) and Monte Carlo Method (MCM), which are reliability methods for the Load and Resistance Factor Design (LRFD) and Limit States Design (LSD) philosophies. Following the same criteria performed by AISI S100, the resistance factors were obtained from the FOSM method. Based on the results, it was found that the desired security level for the LSD philosophy was not achieved. The calculated resistance factors are predominantly lower than the target. However, for the LRFD philosophy, the safety level was achieved, and the resistance factors were higher than the target.pt_BR
dc.description.abstractenLos perfiles de acero conformados en frío son perfiles estructurales muy utilizados en la construcción civil, comúnmente fabricados con perforaciones. El diseño se puede realizar utilizando el método de resistencia directa. Las formulaciones fueron adaptadas por Moen y Schafer (2008), las cuales consideran la presencia de perforaciones. El objetivo de este estudio es investigar la seguridad estructural de columnas con perforaciones en el alma. El cálculo de la capacidad de resistencia se realizó utilizando las formulaciones propuestas por los autores mencionados. Los índices de confiabilidad se determinaron utilizando el Método de Confiabilidad de Primer Orden (FORM), de Primer Orden Segundo Momento (FOSM) y el Método de Montecarlo, que son métodos de confiabilidad para los Factores de Carga y de Resistencia (LRFD) y Estados Límite (LSD). Siguiendo los mismos criterios realizados por el AISI S100, los factores de resistencia se obtuvieron del método FOSM. Con base en los resultados, se encontró que no se logró el nivel de seguridad deseado para la filosofía LSD. Los factores de resistencia calculados son predominantemente más bajos que el objetivo. Sin embargo, para la filosofía LRFD, se logró el nivel de seguridad y los factores de resistencia fueron más altos que el objetivo.pt_BR
dc.identifier.citationJARDIM, R. L. F.; FREITAS, M. S. da R.; BRANDÃO, A. L. R. Resistance factor calibration for perforated cold-formed steel compression members. Revista de Ingeniería de Construcción, v. 37, n. 1, p. 35-46, 2022. Disponível em: <https://www.ricuc.cl/index.php/ric/article/view/1257>. Acesso em: 15 mar. 2023.pt_BR
dc.identifier.doihttp://dx.doi.org/10.7764/RIC.00015.21pt_BR
dc.identifier.issn0718-5073
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/17014
dc.language.isoen_USpt_BR
dc.rightsabertopt_BR
dc.rights.licenseAll articles published by Revista Ingenieria de Construcción, are covereded by Creative commons Attribution 4.0, for further information please click on http://creativecommons.org/licenses/by/4.0. Fonte: Revista Ingenieria de Construcción <https://www.ricuc.cl/index.php/ric/about/submissions#copyrightNotice>. Acesso em: 28 mar. 2023.pt_BR
dc.subjectReliabilitypt_BR
dc.subjectCold-formed steelpt_BR
dc.subjectHolespt_BR
dc.subjectMétodo de resistencia directapt_BR
dc.subjectCompresiónpt_BR
dc.titleResistance factor calibration for perforated cold-formed steel compression members.pt_BR
dc.title.alternativeCalibración del factor de resistencia a la compresión en perfiles de acero conformado en frío perforados.pt_BR
dc.typeArtigo publicado em periodicopt_BR

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
ARTIGO_ResistanceFactorCalibration.pdf
Tamanho:
1.33 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: