Electrical profiling of vibration-induced dewatering of sand.

dc.contributor.authorReis, Jonathan Leandro Martins
dc.contributor.authorLuz, José Aurélio Medeiros da
dc.contributor.authorVardanega, Fábio
dc.date.accessioned2022-09-21T20:00:52Z
dc.date.available2022-09-21T20:00:52Z
dc.date.issued2021pt_BR
dc.description.abstractElectrorresistive profiling of moisture inside a quartz sand bed on a pilot-scale vibrating screen was treated here. As electrode or probe configuration for resistivity measurement is concerned, the classical Wenner α array was used, requiring equal electrode spacing, and correct penetration depth and alignment. Here, the influence of small variations in penetration depth and lack of probe collinearity on the moisture readings, using a digital earth resistance tester and copper wires as probes, was evaluated. The penetration depths studied were 50 mm and 55 mm. In turn, the electrode misalignment tested was 10 mm. The only factor that has caused statistically significant effect in measurements was probe penetration depth, at least under the range tested here.pt_BR
dc.description.abstractenA perfilagem eletrorresistiva da umidade no leito de areia quartzosa sobre tela vibratória em escala piloto foi tratado aqui. No que tange à configuração do eletrodos para medição de eletrorresistividade, o arranjo Wenner alfa clássico foi usado, exigindo espaçamento igual entre os eletrodos e mesma profundidade de penetração e alinhamento corretos. Aqui, a influência de pequenas variações na profundidade de penetração e falta de colinearidade dos eletrodos nas leituras de umidade, usando um eletrorresistivímetro digital e eletrodos de cobre, foi avaliada. As profundidades de penetração estudadas foram de 50 mm e 55 mm. Por sua vez, o desalinhamento testado dos eletrodos foi de 10 mm. O único fator que causou efeito estatisticamente significativo nas medições foi a profundidade de penetração de eletrodo, ao menos na faixa aqui estudada.pt_BR
dc.identifier.citationREIS, J. L. M.; LUZ, J. A. M. da; VARDANEGA, F. Electrical profiling of vibration-induced dewatering of sand. HOLOS, v. 7, 2021. Disponível em: <https://www2.ifrn.edu.br/ojs/index.php/HOLOS/article/view/8952>. Acesso em: 29 abr. 2022.pt_BR
dc.identifier.doihttps://doi.org/10.15628/holos.2020.8952pt_BR
dc.identifier.issn1807-1600
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/15455
dc.language.isoen_USpt_BR
dc.rightsabertopt_BR
dc.rights.licenseEste é um artigo publicado em acesso aberto sob uma licença Creative Commons. Fonte: o PDF do artigo.pt_BR
dc.subjectElectroresistivitypt_BR
dc.subjectMoisturept_BR
dc.subjectWenner alpha arraypt_BR
dc.subjectSensitivity analysispt_BR
dc.titleElectrical profiling of vibration-induced dewatering of sand.pt_BR
dc.title.alternativePerfilagem elétrica de desaguamento de areia induzido por vibração.pt_BR
dc.typeArtigo publicado em periodicopt_BR

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
ARTIGO_ElectricalProfilingVibration.pdf
Tamanho:
541.61 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: