A study of the impacts caused by unbalanced voltage (2%) in isolated synchronous generators.

dc.contributor.authorVanço, Wagner Eduardo
dc.contributor.authorSilva, Fernando Bento
dc.contributor.authorMonteiro, José Roberto Boffino de Almeida
dc.date.accessioned2022-09-15T21:24:55Z
dc.date.available2022-09-15T21:24:55Z
dc.date.issued2019pt_BR
dc.description.abstractThis paper presents an analysis of the oscillations caused by unbalanced loads in salient pole synchronous generators that operate in isolation under steady state. The oscillatory disturbances, arising from the second-order harmonics, may have or have the potential to cause electromechanical damage to the salient pole synchronous generator. In this paper, the goal is to identify and quantify the magnitude of the electromagnetic torque, which assumes an oscillatory form due to the current component from the negative sequence, caused by unbalanced currents. The self-same analysis was included for second-harmonic voltage oscillations in the qd0 domain, the currents induced on the damper windings together with the oscillation of the load angle and on the field current. These oscillations situated on the synchronous generator are analyzed for a degree of voltage unbalance close to 2% which is an acceptable value according to international regulations for power supply from distribution networks, and this same degree of tolerated voltage unbalance will be used herein for isolated synchronous generators.pt_BR
dc.identifier.citationVANÇO, W. E.; SILVA, F. B.; MONTEIRO, J. R. B. A. A study of the impacts caused by unbalanced voltage (2%) in isolated synchronous generators. IEEE Access, v. 7, p. 72956-72963, 2019. Disponível em: <https://ieeexplore.ieee.org/document/8725501>. Acesso em: 29 abr. 2022.pt_BR
dc.identifier.doihttps://doi.org/10.1109/ACCESS.2019.2919298pt_BR
dc.identifier.issn2169-3536
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/15318
dc.identifier.uri2https://ieeexplore.ieee.org/document/8725501pt_BR
dc.language.isoen_USpt_BR
dc.rightsrestritopt_BR
dc.subjectElectrical lossespt_BR
dc.subjectOscillating torquept_BR
dc.subjectOscillationpt_BR
dc.subjectSalient polespt_BR
dc.subjectSecond harmonicpt_BR
dc.titleA study of the impacts caused by unbalanced voltage (2%) in isolated synchronous generators.pt_BR
dc.typeArtigo publicado em periodicopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
ARTIGO_StudyImpactsCaused.pdf
Tamanho:
4.85 MB
Formato:
Adobe Portable Document Format
Descrição:
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: