Análise da eficiência do sistema de vedação da fundação em granito de uma barragem de concreto.
dc.contributor.advisor | Assis, André Pacheco de | pt_BR |
dc.contributor.author | Lopes, Marieli Biondo | |
dc.date.accessioned | 2015-05-12T13:31:18Z | |
dc.date.available | 2015-05-12T13:31:18Z | |
dc.date.issued | 2015 | |
dc.description | Programa de Pós-Graduação em Engenharia Geotécnica. Núcleo de Geotecnia, Escola de Minas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | O Brasil possui um dos maiores parques hidrelétricos do mundo, com capacidade de geração de energia comparado à posição da Arábia Saudita na extração de petróleo. Com isso é importante avançar em conceitos e técnicas, indo além das metodologias já consagradas. Este estudo aprofunda os conhecimentos sobre a eficiência de tratamentos de vedação em fundações rochosas de barragens de concreto, com o uso de cortinas de injeção com calda de cimento. Tratamentos como este permitem a redução do coeficiente de permeabilidade do maciço e a subpressão. Para atestar a real eficiência dos serviços de vedação no vertedouro da UHE Jirau, ela foi realizada através de três análises: redução do coeficiente de permeabilidade, redução da absorção de calda de cimento e redução da subpressão. Na primeira análise, observando a permeabilidade antes (furos de sondagem e furos obrigatórios de injeção) e depois (furos de verificação), concluiu-se que o maciço possui boas características mecânicas e hidráulicas (mesmo com a presença de fraturas sub-horizontais) por possuir coeficientes de permeabilidade baixos, sendo que a injeção auxiliou em uma pequena redução deste coeficiente, passando da ordem de 10-5 para 10-6 cm/s.. Na segunda análise, através do acompanhamento pari passu de consumo de calda, observando o maciço de forma geral, verificou-se que houve redução de absorção de calda de 27% e com isso a atividade de injeção foi funcional. Na terceira e última análise, verificando as leituras de piezometria, estas constataram que a subpressão não ultrapassou os limites referenciados em projetos, porém como não foi utilizado o método racional com retroanálise, não foi quantificado o quanto a cortina de injeção contribuiu para estes valores. De forma geral, adotando o critério de Cruz (2004), que prescreve que fundações com coeficientes menores que 5 x 10-4 cm/s não há necessidade de tratamento, conclui-se que as atividades de injeção na UHE Jirau poderiam ter sido anuladas ou reduzidas, reduzindo o prazo e custo destes serviços. | pt_BR |
dc.description.abstracten | Brazil has one of the largest hydroelectric parks in the world, with power generation capacity compared to the position of Saudi Arabia in oil extraction. With this important to advance concepts and techniques going, beyond the already established methodologies. This study deepens the knowledge about the effectiveness of sealing treatments on rocky foundations of concrete dams, with the use of injection curtains with mortar. Treatments such as this allow the reduction of the mass permeability coefficient and the underpressure. To attest to the real efficiency of sealing services in the spillway of UHE Jirau, it was performed through three analyzes: reduction of permeability coefficient, reduced cement slurry absorption and reduction of negative pressure. In the first analysis, observing the permeability before (boreholes and required injection holes) and then (check holes), it was concluded that the mass has good mechanical and hydraulic characteristics (even in the presence of sub-horizontal fractures) by has low water permeability coefficient being helped in the injection a small reduction in this ratio, the order of 10-5 to 10-6 cm / sec .. In the second analysis, by simultaneously monituring liquid consumption accompanying liquid consumption by observing the massive general, it was found that there was a reduction sauce absorption of 27% and with this the injection activity was functional. The third and final analysis, checking the readings of piezometric, they found that the negative pressure did not exceed the limits referenced in projects, but was not used as the rational method with back analysis, has not been quantified as the making injection membranes contributed to these values. In general, adopting the criteria Cruz (2004), which provides that foundations with lower coefficients than 5 x 10-4 cm / s dont need treatment, it is concluded that the injection activities at UHE Jirau could have been canceled or reduced, reducing the time and cost of these services. | |
dc.identifier.citation | LOPES, Marieli Biondo. Análise da eficiência do sistema de vedação da fundação em granito de uma barragem de concreto. 2015. 162 f. Dissertação (Mestrado em Engenharia Geotécnica) – Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2015. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/5291 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 05/05/2015 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação. | pt_BR |
dc.subject | Barragens | pt_BR |
dc.subject | Vedação - tecnologia | pt_BR |
dc.subject | Permeabilidade | pt_BR |
dc.subject | Geotecnia de barragens | pt_BR |
dc.title | Análise da eficiência do sistema de vedação da fundação em granito de uma barragem de concreto. | pt_BR |
dc.type | Dissertacao | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- DISSERTAÇÃO_AnáliseEficiênciaSistema.pdf
- Tamanho:
- 6.94 MB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- license.txt
- Tamanho:
- 2.57 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: