Dimensionamento à punção de lajes lisas apoiadas em pilares de seção transversal elíptica e semi-elíptica.
dc.contributor.advisor | Rocha, Paulo Anderson Santana | pt_BR |
dc.contributor.author | Faria, Jhonatan Willian Souza | |
dc.contributor.referee | Rocha, Paulo Anderson Santana | pt_BR |
dc.contributor.referee | Martins, Jaime Florêncio | pt_BR |
dc.contributor.referee | Galvão, Alexandre da Silva | pt_BR |
dc.date.accessioned | 2018-03-16T15:35:45Z | |
dc.date.available | 2018-03-16T15:35:45Z | |
dc.date.issued | 2018 | |
dc.description | Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | O presente trabalho tem como principal objetivo realizar de forma automática o dimensionamento à punção de duas lajes lisas de concreto armado, sendo a primeira apoiada em um pilar com seção transversal elíptica e a segunda laje apoiada em um pilar com seção transversal semi-elíptica. Inicialmente compararam-se as respostas dos parâmetros relevantes para a realização do projeto das lajes com os resultados obtidos a partir do software AutoCAD. Lembrando que nesta pesquisa os resultados foram determinados através de alguns métodos numéricos e com o auxílio de soluções analíticas. Posteriormente, construiu-se a curva de interação de um pilar de concreto armado de seção transversal semi-elíptica. Para a obtenção da curva utilizou-se a Regra dos Trapézios e as equações de compatibilidade de deformações e de equilíbrio correspondentes a cada domínio de deformação tomando por base a ABNT NBR 6118 (2014). Vale ressaltar que no presente trabalho propõem-se duas equações: uma para calcular o centroide de cada região comprimida e outra para calcular a área de cada parcela comprimida da seção semi-elíptica. Após as intervenções no código computacional, realizou-se o dimensionamento das lajes lisas à punção seguindo as prescrições normativas da ABNT NBR 6118 (2014) e para isso utilizou-se a linguagem computacional FORTRAN 90. | pt_BR |
dc.description.abstracten | The main objective of this work is to perform automatically the punching shear design of two reinforced concrete flat slabs, the first being supported on a column with an elliptical cross-section and the second slab supported on a column with a semielliptical cross-section. We initially compared the responses of the parameters relevant to the design of slabs with the results obtained from AutoCAD software. Recalling that in this research the results were determined through some numerical methods and with the aid of analytical solutions. Subsequently, the interaction curve for the cross-section of a reinforced concrete column of semi-elliptical cross-section was constructed. In order to obtain the curve, we used the Trapezius Rule and the strain and equilibrium compatibility equations corresponding to each strain domain based on ABNT NBR 6118 (2014). It is worth mentioning that in the present work two equations are proposed: one to calculate the centroid of each compressed region and another to calculate the area of each compressed portion of the semi-elliptical section. After the interventions in the computational code, the dimensioning of the flat slabs was performed according to the normative prescriptions of ABNT NBR 6118 (2014) and for this the FORTRAN 90 computer language was used. | pt_BR |
dc.identifier.citation | FARIA, Jhonatan Willian Souza. Dimensionamento à punção de lajes lisas apoiadas em pilares de seção transversal elíptica e semi-elíptica. 2018. 76 f. Dissertação (Mestrado em Engenharia Civil) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2018. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/9662 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 05/03/2018 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Não permite a adaptação. | pt_BR |
dc.subject | Desenho - engenharia - dimensionamento | pt_BR |
dc.subject | Colunas de concreto | pt_BR |
dc.subject | Lajes de concreto | pt_BR |
dc.subject | Construção Metálica | pt_BR |
dc.title | Dimensionamento à punção de lajes lisas apoiadas em pilares de seção transversal elíptica e semi-elíptica. | pt_BR |
dc.title.alternative | Punching shear design of flat slabs supported on elliptical and semi-elliptical cross-section column. | |
dc.type | Dissertacao | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- DISSERTAÇÃO_DimensionamentoPunçãoLajes.pdf
- Tamanho:
- 1.8 MB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- license.txt
- Tamanho:
- 924 B
- Formato:
- Item-specific license agreed upon to submission
- Descrição: