CdWO4-on-MEH-PPV:PS as a candidate for real-time dosimeters.
dc.contributor.author | Silva, M. M. | |
dc.contributor.author | Novais, S. M. V. | |
dc.contributor.author | Silva, E. S. S. | |
dc.contributor.author | Schimitberger, Thiago | |
dc.contributor.author | Macedo, Z. S. | |
dc.contributor.author | Bianchi, Rodrigo Fernando | |
dc.date.accessioned | 2015-03-16T19:04:51Z | |
dc.date.available | 2015-03-16T19:04:51Z | |
dc.date.issued | 2012 | |
dc.description.abstract | We report on the investigations about the modification of optical properties induced by X-rays onto film detectors of cadmium tungstate (CdWO4), poly[2-methoxy-5(20 -ethylhexyloxy)-p-phenylenevinylene] (MEH-PPV) and polystyrene (PS) This device takes advantage of reduction of spectral overlap between the radioluminescence (RL) of CdWO4 and the absorption of MEH-PPV as it is exposed to radiation, forming the basis of a new dosimeter that is capable of converting the orange-red radioluminescence of PS:MEH-PPV:CdWO4 into green. We propose an explanation of the optical processes occurring in MEHPPV:CdWO4 in terms of the radiation hardness of CdWO4 combined to the RL-induced degradation of MEH-PPV. | pt_BR |
dc.identifier.citation | SILVA, M. M. et al. CdWO4-on-MEH-PPV:PS as a candidate for real-time dosimeters. Materials Chemistry and Physics, v. 136, p. 317-319, 2012. Disponível em: <http://www.sciencedirect.com/science/article/pii/S025405841200733X>. Acesso em: 23 fev. 2015. | pt_BR |
dc.identifier.doi | https://doi.org/10.1016/j.matchemphys.2012.08.022 | |
dc.identifier.issn | 0254-0584 | |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/4672 | |
dc.language.iso | en_US | pt_BR |
dc.rights.license | O periódico Materials Chemistry and Physics concede permissão para depósito do artigo no Repositório Institucional da UFOP. Número da licença: 3565381282486. | pt_BR |
dc.subject | Composite materials | pt_BR |
dc.subject | Optical materials | pt_BR |
dc.subject | Irradiation effects | pt_BR |
dc.subject | Luminescence | pt_BR |
dc.title | CdWO4-on-MEH-PPV:PS as a candidate for real-time dosimeters. | pt_BR |
dc.type | Artigo publicado em periodico | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- ARTIGO_CdWO4MEHPPV.pdf
- Tamanho:
- 346.14 KB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- license.txt
- Tamanho:
- 2.57 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: