Recomendações para o aperfeiçoamento dos sistemas de construção industrializados que utilizam aço, com ênfase em fechamento metálico.

dc.contributor.advisorSouza, Henor Artur dept_BR
dc.contributor.authorFaria, Marcela Assunção
dc.contributor.refereeSouza, Henor Artur dept_BR
dc.contributor.refereeGomes, Adriano Pintopt_BR
dc.contributor.refereeMoreira, Thiago Augusto Araújopt_BR
dc.contributor.refereeMarques, Aline Calazanspt_BR
dc.date.accessioned2022-04-11T18:43:03Z
dc.date.available2022-04-11T18:43:03Z
dc.date.issued2019pt_BR
dc.descriptionPrograma de Pós-Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractA baixa qualidade dos ambientes internos das edificações no país está diretamente relacionada a uma resposta inadequada dos sistemas de construção usuais aos condicionantes climáticos do local onde a edificação está inserida. O resultado desse baixo desempenho térmico de edificações residenciais ocasiona o aumento de consumo de energia pelo uso de condicionamento artificial para que os usuários alcancem o conforto desejado e esperado. O Brasil possui uma diversidade climática muito grande, com diferentes demandas para o desempenho térmico ideal, em que as variáveis que impactam no desempenho térmico têm influências diferenciadas dependendo da localidade e tipo de envoltória. Neste sentido, todos os conceitos de arquitetura bioclimática devem estar de acordo com os materiais e com o processo de construção utilizado. Quando não é feito um estudo prévio do desempenho térmico de uma edificação na fase de projeto, os efeitos desagradáveis ao usuário aparecem depois que a edificação está pronta, e trazem consigo problemas como temperaturas internas altas demais no verão ou baixas demais no inverno acompanhando as oscilações externas nos ambientes internos. Notam-se estudos sempre para edificações multifamiliares e no setor de habitação social, sendo também de igual importância o seguimento residencial unifamiliar de médio para alto padrão por ser exatamente o seguimento que não poupa gastos energéticos para atingirem seu máximo conforto interno, por maior tempo possível, um setor que não apresenta crise financeira e cresce constantemente. Nesse sentido a necessidade de incentivar novas práticas aplicáveis ao setor residencial unifamiliar é uma necessidade urgente, que tem pouca visibilidade tanto no ensino quanto na prática. Essa pesquisa traz recomendações a partir de simulações numéricas utilizando o programa Energyplus (versão 8.9.0), conforme os requisitos na norma NBR 15.575 e visando o conforto térmico do usuário, testando dois novos produtos na aplicação para fechamento externo no setor residencial unifamiliar, os painéis compósitos ACM (Aluminium Composite Material) e as telhas termoacústicas (sanduíche). São analisados os resultados encontrados para os dias típicos de inverno e verão correspondentes às oito zonas bioclimáticas e comparados com as recomendações da norma NBR 15.575, gerando um modelo fatorial duplo para as três zonas bioclimáticas críticas, ZB1 cidade representativa Curitiba, na análise do inverno, ZB3 cidade representativa São Paulo inverno e verão, e para a ZB8 cidade representativa Manaus na análise de verão. Utiliza-se o experimento fatorial abrangendo as principais variáveis de desempenho térmico como absortância, ventilação natural e propriedades termofísicas da envoltória. Os resultados obtidos são significativos: observa-se que a telha termoacústica mantém a temperatura estável independente das oscilações externas, enquanto os painéis de ACM acompanham as oscilações externas, não correspondendo às expectativas de conforto e necessitando de outras estratégias para adequar o desempenho térmico.pt_BR
dc.description.abstractenThe low thermal performance of residential buildings in Brazil is directly related to an inappropriate reaction of the buildings construction system to the climatic conditions where the building is located. The result of this low thermal performance of residential buildings increases the energy consumption by the usage of artificial conditioning system as the consumers look for a comfortable environment. Brazil holds a considerable climatic diversity with different demands to reach the ideal thermal performance. The variables that impact the thermal performance have different influences depending on the place the buildings are located and how they are constructed. In this way all the bioclimatic architecture approach should be according to the materials and to the construction processes. When the thermal performance is not studied before the building construction and its previous project, different problems appear after the building is constructed. During the summer it could suffer of really high temperature inside the building, and during the winter it could occur the opposite, it could be really cold as the temperature inside the building follows the external oscillations. There are several studies related to multifamily residential buildings and social housing sector. It is important to mention that studies related to the unifamily residential buildings should have a special attention as this segment doesn’t save energy costs to achieve their maximum comfort standards. And this sector is the one that isn’t in financial crises and is the one that is constantly growing. According to this, it is extremely relevant to encourage new practices to improve the unifamily sector, as it has a lack of visibility in its studies as well as in the practical way. This paper aims to bring some recommendations trough numerical simulations using the Energyplus program (version 8.9.0) according to the requirements in NBR 15.575 that with the propose to provide thermal comfort for the consumer, testing the application of two new products for external closure in the unifamily residential sector, the ACM panels and thermoacoustic tiles. It will be analysed results for the typical winter and summer days corresponding to eight bioclimatic areas and compared with the requirements in NBR 15.575 generating a double factorial model for the tree critical areas. ZB1 represents Curitiba, during the winter. ZB3 represents São Paulo during the winter and summer. ZB8 represents Manaus during the summer analyses. The factorial experiment is used to cover the main thermal performance variations such as absorption, natural ventilation, and thermophysical properties of the envelope. The results obtained are significant. The results obtained are significant: it is observed that the thermoacoustic tile maintains a stable temperature regardless of external oscillations, while ACM panels follow external oscillations, not meeting expectations of comfort and requiring other strategies to adjust termal performance.pt_BR
dc.identifier.citationFARIA, Marcela Assunção. Recomendações para o aperfeiçoamento dos sistemas de construção industrializados que utilizam aço, com ênfase em fechamento metálico. 2019. 150 f. Tese (Doutorado em Engenharia Civil) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2019.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/jspui/handle/123456789/14862
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 07/04/2022 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.pt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectArquitetura - aspectos ambientaispt_BR
dc.subjectConstrução metálica - envoltória metálicapt_BR
dc.subjectConforto térmicopt_BR
dc.subjectArquitetura bioclimáticapt_BR
dc.titleRecomendações para o aperfeiçoamento dos sistemas de construção industrializados que utilizam aço, com ênfase em fechamento metálico.pt_BR
dc.typeTesept_BR

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
TESE_RecomendaçõesAperfeiçoamentoSistemas.pdf
Tamanho:
3.4 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: