Influência de diferentes tipos de minério de ferro na umidade do sinter feed.
dc.contributor.advisor | Rodrigues, Otávia Martins Silva | pt_BR |
dc.contributor.advisor | Reis, Érica Linhares | pt_BR |
dc.contributor.author | Quites, Noel Aparecido Siqueira | |
dc.contributor.referee | Reis, Érica Linhares | pt_BR |
dc.contributor.referee | Alexandrino, Júnia Soares | pt_BR |
dc.contributor.referee | Lima, Rosa Malena Fernandes | pt_BR |
dc.date.accessioned | 2020-03-03T11:55:46Z | |
dc.date.available | 2020-03-03T11:55:46Z | |
dc.date.issued | 2018 | |
dc.description | Programa de Pós-Graduação em Engenharia Mineral. Departamento de Engenharia de Minas, Escola de Minas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | Frequentemente, a Instalação de Tratamento de Minérios D (ITM-D) da Mina do Pico (Vale) produz sinter feed (SF) com umidade acima do valor especificado para a unidade operacional, o qual deve ser inferior a 12,5%. Durante a etapa de classificação adiciona-se água para lavagem dos finos (-0,15 mm) presentes na alimentação da usina, o que torna a umidade um importante item de controle. O desaguamento é a etapa final do beneficiamento, esta etapa é responsável pelo ajuste da umidade do SF, entretanto, muitas vezes, as operações de desaguamento da unidade não alcançam o resultado esperado. Este trabalho caracterizou 6 diferentes amostras de minério de ferro da Mina do Pico, de forma a permitir um melhor entendimento da influência da litologia no desaguamento. Todas as amostras foram preparadas em laboratório para ajuste granulométrico no intervalo correspondente ao SF (-19,1mm +0,15mm). Em seguida elas foram caracterizadas: análise granulométrica, análise química por faixa granulométrica, determinação de densidade e área superficial específica, B.E.T, difração de raios-X/Rietveld, microscopia eletrônica de varredura (MEV) e avaliação quantitativa de materiais por microscopia eletrônica de varredura (QEMSCAN). Realizaram-se ensaios de drenabilidade, com cada litologia, para acompanhar o escoamento da água e determinar o valor de umidade residual. Realizaram-se também ensaios de drenabilidade utilizando 300 g/t de um reagente auxiliar para desaguamento. Para conclusão do trabalho relacionaram-se as informações obtidas pelas técnicas de caracterização e pelos testes de drenabilidade. Os resultados indicaram que a litologia tem significativa influência no escoamento da água e no valor de umidade residual. Os minerais hematita, goethita, quartzo, gibbsita e magnetita foram identificados em todas as amostras. As litologias com maior presença de goethita e maior proporção de partículas finas reteram mais umidade, sendo o maior valor igual a 15,5%, 3% acima do desejado. A presença do reagente auxiliar decresceu o valor de umidade retida para as 6 litologias estudadas, sendo a maior redução para a litologia HG, 3,14 pontos percentuais. | pt_BR |
dc.description.abstracten | Often, ITM-D mineral procesing plant at Pico Mine (Vale) produces sinter feed (SF) with moisture above the value specified for the operating unit, which should be less than 12.5%. During the classification, water is added to wash the fines (- 0.15 mm) present in the feed of the plant, which makes moisture an important control parameter. The process of dewatering is the final stage of the beneficiation, this step is responsible for the adjustment of the moisture of the SF, however, frequently the dewatering operations of the ITM-D do not reach the expected result. This work characterized 6 different samples of iron ore from the Pico Mine region, in order to allow a better understanding of the influence of lithology on the dewatering. All samples were prepared in the laboratory to adjust the size in the granulometric range corresponding to SF (-19.1mm + 0.15mm). They were characterized by the following techniques: granulometric analysis, chemical analysis by granulometric range, determination of density and specific surface area, porosimetry, X-ray diffraction / Rietveld, scanning electron microscopy (SEM) and quantitative evaluation of materials by scanning electron microscopy (QEMSCAN). Dewatering tests were carried out, in each lithology, to analyze the flow of water and to determine the value of residual moisture. Dewatering tests were also performed by using an auxiliary reagent (30 g/t). The information obtained by the characterization techniques and the drainage tests were combined to make the conclusion of the study. The results indicated that lithology has a significant influence on dewatering and residual moisture value. The minerals hematite, goethite, quartz, gibbsite and magnetite were identified in all samples. The lithologies with the highest presence of goethite and proportion of fine particles retained more moisture, being the highest value 15.5%, 3 points higher than aimed. The presence of the auxiliary reagent decreased the moisture content retained for the 6 lithologies studied. | pt_BR |
dc.identifier.citation | QUITES, Noel Aparecido Siqueira. Influência de diferentes tipos de minério de ferro na umidade do sinter feed. 2018. 102 f. Dissertação (Mestrado em Engenharia Mineral) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2018. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/handle/123456789/11938 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 20/02/2020 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação. | pt_BR |
dc.subject | Litologia | pt_BR |
dc.subject | Sinterização | pt_BR |
dc.subject | Beneficiamento de minério - desaguamento | pt_BR |
dc.title | Influência de diferentes tipos de minério de ferro na umidade do sinter feed. | pt_BR |
dc.type | Dissertacao | pt_BR |