Avaliação do desempenho térmico de sistemas de fechamento interno e externo em uma edificação estruturada em aço.

dc.contributor.advisorRibas, Rovadávia Aline de Jesuspt_BR
dc.contributor.advisorGomes, Adriano Pintopt_BR
dc.contributor.authorOliveira, Gustavo Gomes de
dc.contributor.refereeRibas, Rovadávia Aline de Jesuspt_BR
dc.contributor.refereeGomes, Adriano Pintopt_BR
dc.contributor.refereePaula, Geraldo Donizetti dept_BR
dc.contributor.refereeMarçal, Viviane Gomespt_BR
dc.date.accessioned2020-06-30T15:52:31Z
dc.date.available2020-06-30T15:52:31Z
dc.date.issued2019
dc.descriptionPrograma de Pós-Graduação em Construção Metálica. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto.pt_BR
dc.description.abstractComo as questões de conforto térmico e suas relações com índice de produtividade e bem-estar têm se tornado importantes, fazem-se necessários estudos que visem atender a essa demanda da sociedade. Em edificações, um sistema de fechamento adequado ao clima local pode reduzir o gasto com energia elétrica e contribuir positivamente no aspecto ambiental e econômico. Nesse contexto, essa dissertação tem como objetivo analisar o desempenho térmico de sistemas de fechamento propostos para uma edificação estruturada em aço. Avalia-se um edifício residencial localizado em Cachoeira do Campo, distrito de Ouro Preto, MG. A edificação de três pavimentos possui pilares e vigas em aço, fechamento externo e interno ausentes e cobertura estruturada em aço. Para a análise são realizadas simulações via software EnergyPlus, do desempenho térmico de vários sistemas de fechamento, levando-se em conta as condições climáticas locais nas condições de inverno e de verão: painéis de placa cimentícia (PLC), gesso acartonado (GEA), pré-moldado de concreto (PMC), concreto celular autoclavado (CCA), poliestireno expandido (EPS), Exterior Insulation Finishing System (EIFS), vidro (VDO), madeira - Oriented Strand Board (OSB) e alvenaria (ATC). Os sistemas de fechamento não foram instalados, justificando-se esse estudo. Apontam-se sistemas de fechamento mais viáveis, do ponto de vista econômico e ambiental, que podem se tornar exemplo para possíveis construções no distrito. Dentre os fechamentos analisados alguns demonstram ser melhores no verão e outros no inverno, não sendo possível afirmar qual deles resulta no melhor desempenho térmico. Porém destacam-se alguns que atingem um desempenho adequado nas duas situações, que são: ATC, EIFS (tanto utilizado com GEA quanto com OSB), OSB, VDO combinado com ATC, EPS. A partir dos resultados obtidos durante a pesquisa, chega-se a uma avaliação qualitativa da edificação em termos de desempenho térmico, apresentando-se uma proposta justificável do ponto de vista econômico e ambiental, para o sistema de fechamento.pt_BR
dc.description.abstractenAs the issues of thermal comfort and their relationship with productivity index and well-being have become important, studies are needed to meet this societal demand. In buildings, a closure system suitable for the local climate can reduce electricity costs and contribute positively to the environmental and economic aspects. In this context, this dissertation aims to address the design of closure systems and their interference on the thermal performance of steel structured buildings. It is a residential building located in Cachoeira do Campo, district of Ouro Preto, MG. The building has steel pillars and beams, missing external and internal closures and a structured steel roof. All their connections are bolted and the three floors are covered with precast concrete slab. Through an exploratory investigation, photographic survey and data collection, a mapping is made about the conditions of the building and its surroundings, identifying its local climate in both winter and summer. EnergyPlus software simulations are performed of the thermal performance of various closure systems, taking into account local climatic conditions: cementitious panels (PLC), plasterboard (CCA), precast concrete (PMC), autoclaved cellular concrete (CCA), expanded polystyrene (EPS), Exterior Insulation Finishing System (EIFS), glass (VDO), wood - Oriented Strand Board (OSB) and masonry (ATC). The closure systems were not installed, justifying this study. More economically and environmentally viable closing systems are pointed out, which can be an example for possible construction in the district. Among industrialized closures, it is not possible to state exactly which results in the best thermal performance, as some prove to be better in summer and others in winter. However, we highlight some that achieve great regularity in both situations: ATC, EIFS (both used with GEA and OSB), OSB, VDO combined with ATC, EPS. From the results obtained during the research, it is possible to reach a qualitative evaluation of the building in terms of thermal performance, presenting a justifiable proposal from the economic and environmental point of view, for the closure system.pt_BR
dc.identifier.citationOLIVEIRA, Gustavo Gomes de. Avaliação do desempenho térmico de sistemas de fechamento interno e externo em uma edificação estruturada em aço. 2019. 109 f. Dissertação (Mestrado Profissional em Construção Metálica) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2019.pt_BR
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/12400
dc.language.isopt_BRpt_BR
dc.rightsabertopt_BR
dc.rights.licenseAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 26/06/2020 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho desde que sejam citados o autor e o licenciante.pt_BR
dc.subjectEdificaçõespt_BR
dc.subjectEstruturas em açopt_BR
dc.subjectDesempenho térmicopt_BR
dc.subjectSistemas de fechamentopt_BR
dc.subjectSimulação computacionalpt_BR
dc.titleAvaliação do desempenho térmico de sistemas de fechamento interno e externo em uma edificação estruturada em aço.pt_BR
dc.typeDissertacaopt_BR

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Imagem de Miniatura
Nome:
DISSERTAÇÃO_AvaliaçãoDesempenhoTérmico.pdf
Tamanho:
2.3 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura Disponível
Nome:
license.txt
Tamanho:
924 B
Formato:
Item-specific license agreed upon to submission
Descrição: