Análise da influência dos contraventamentos em painéis de sistemas de armazenagem.
dc.contributor.advisor | Sarmanho, Arlene Maria Cunha | pt_BR |
dc.contributor.advisor | Alves, Vinicius Nicchio | pt_BR |
dc.contributor.author | Dias, Otávio Teixeira | |
dc.contributor.referee | Sarmanho, Arlene Maria Cunha | pt_BR |
dc.contributor.referee | Alves, Vinicius Nicchio | pt_BR |
dc.contributor.referee | Mesacasa Junior, Enio Carlos | pt_BR |
dc.contributor.referee | Souza, Flávio Teixeira de | pt_BR |
dc.date.accessioned | 2023-08-25T20:36:22Z | |
dc.date.available | 2023-08-25T20:36:22Z | |
dc.date.issued | 2021 | pt_BR |
dc.description | Programa de Pós-Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | Os sistemas de armazenagem industrial, ou racks, são estruturas utilizadas para armazenar e distribuir produtos manufaturados. Em geral, eles são fabricados em perfil formado à frio, de chapa fina, que garante aos perfis boa relação massa/resistência, flexibilidade da forma da seção transversal, além de facilidade de produção, manuseio e transporte. Nos Racks, a estabilidade no plano transversal está relacionada aos painéis contraventados, também chamados de montantes. O objetivo deste trabalho é analisar a influência dos contraventamentos e diferentes arranjos no comportamento e resistência dos montantes que formam o sistema de armazenagem. Para tanto, foi desenvolvida uma campanha experimental que determinou a capacidade de carga axial de montantes, com colunas de seção transversal do tipo rack, considerando variações no comprimento, nas condições de apoio e na disposição dos contraventamentos, através da montagem alternativa do ensaio de compressão descrito na norma BS EN 15512 (2009). Os resultados indicaram a dominância da flambagem distorcional como modo de falha, com características abruptas, além de pouca influência das condições de apoio na capacidade de carga dos protótipos. As alterações realizadas na configuração dos contraventamentos não são se mostraram suficientes para amenizar a falha, entretanto permitiram o crescimento da capacidade resistente. Outrossim, os ensaios realizados indicaram mecanismos de instabilidade que propiciaram estudos adicionais e a proposição de um aparato de enrijecimento da coluna, aumentando a carga de flambagem quanto ao modo distorcional. Foram determinadas a capacidade de carga experimentais de colunas isoladas e montantes com os aparatos de travamento propostos. Além da capacidade de carga, foram analisados os modos de instabilidade e sua relação com a carga última dos protótipos, através da análise dos deslocamentos das colunas. Notou-se que a utilização do aparato de travamento induz a falha no menor comprimento destravado, ocasionado pela mudança na seção transversal da coluna, que passa a se comportar como uma seção fechada na região onde esses elementos são fixados. | pt_BR |
dc.description.abstracten | Industrial storage systems, or racks, are structures used to store and distribute manufactured products. In general, they are manufactured in cold-formed steel of thin sheet profiles, which guarantee good mass/resistance ratio, flexibility in the shape of the cross section, ease of production, handling and transportation. On racks, stability in the transversal plane is associated with uprights. The aim of this work is to analyze the influence of braces and different arrangements on the behavior and resistance of the uprights that form the storage system. For this purpose, an experimental campaign was developed that determined the axial load capacity of uprights, with rack cross-section columns, considering variations in length, support conditions and the arrangement of braces, through the alternative assembly of the compression test described in BS EN 15512 (2009). The results indicated the dominance of distorcional buckling as a failure mode, with sudden failures, besides little influence of the support conditions on the prototypes load capacity. The changes made to the brace configuration are not sufficient to alleviate the failure, however, they allow the gain of resistant capacity. Furthermore, the tests carried out indicated instability mechanisms that led to additional studies and the proposal of a column stiffening apparatus, increasing the buckling load in terms of distorcional mode. The experimental load capacity of isolated columns and uprights with the proposed column stiffening apparatus were determined. In addition to load capacity, the modes of instability and their relationship with the ultimate load of the prototypes were analyzed, through the analysis of the columns’ displacements. It was noted that the use of the column stiffening apparatus induces failure in the shortest unlocked length, caused by the change in the cross section of the column, which behaves as a closed section in the region where they are fixed. | pt_BR |
dc.identifier.citation | DIAS, Otávio Teixeira. Análise da influência dos contraventamentos em painéis de sistemas de armazenagem. 2021. 109 f. Dissertação (Mestrado em Engenharia Civil) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2021. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/jspui/handle/123456789/17354 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 03/06/2021 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais. | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Construção metálica | pt_BR |
dc.subject | Perfis formados a frio | pt_BR |
dc.subject | Administração de empresas - sistemas de armazenagem | pt_BR |
dc.subject | Estantes mobiliário - rack | pt_BR |
dc.subject | Estabilidade estrutural | pt_BR |
dc.title | Análise da influência dos contraventamentos em painéis de sistemas de armazenagem. | pt_BR |
dc.type | Dissertacao | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- DISSERTAÇÃO_AnáliseInfluênciaContraventos.pdf
- Tamanho:
- 5.36 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do pacote
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission