Digital single voltage loop control of a VSI with LC output filter.
Data
2018
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
This paper deals with the output voltage control problem of a three-phase three-wire voltage source
Inverter (VSI) with LC output filter. A novel discrete-time active damping technique is proposed in order to
damp the filter resonance without the need of current feedback. The method is based on an inner voltage
feedback with digital lead compensator on the feedback path. A modified digital resonant controller
is also proposed to reject the current harmonic disturbance drawn by nonlinear loads. The resonant
controllers are connected in series and the design is based on its zeros damping. Results from a small
scale experimental setup are used to validate the proposed control strategy.
Descrição
Palavras-chave
Voltage source inverter, Active damping, Single voltage loop and modified digital, Resonant controller
Citação
SOUZA, I. D. N. de et al. Digital single voltage loop control of a VSI with LC output filter. Sustainable Energy, Grids and Networks, v. 16, p. 145-155, 2018. Disponível em: <https://www.sciencedirect.com/science/article/pii/S2352467718300092>. Acesso em: 15 fev. 2019.