Construction of analytical curve fit models for simvastatin using ordinary and weighted least squares methods.

dc.contributor.authorMarinho, Flávia Dias Marques
dc.contributor.authorReis, Ilka Afonso
dc.contributor.authorSoares, Cristina Duarte Vianna
dc.date.accessioned2015-05-26T18:32:50Z
dc.date.available2015-05-26T18:32:50Z
dc.date.issued2013
dc.description.abstractMétodos analíticos requerem modelos adequados de ajuste de curva para expressar confiabilidade. Métodos dos mínimos quadrados ordinários ou ponderado (OLSM ou WLSM, respectivamente) foram usados para determinar o modelo matemático mais adequado à curva analítica, iniciando-se do método mais simples (linear) até o quadrático. A normalidade e a homocedasticidade dos resíduos dos modelos foram avaliadas. Curvas analíticas foram construídas pela injeção de 1, 5, 10, 15 e 20 L de sinvastatina 40 μg mL–1 (40, 200, 400, 600 e 800 ng) ou de 10 L de sinvastatina 4, 20, 40, 60 e 80 μg mL–1, empregando cromatografia líquida de alta eficiência com detecção por arranjo de diodos (238 nm). Os melhores modelos foram o linear e o quadrático observados para os conjuntos de dados massas e concentrações, respectivamente. Na faixa de trabalho considerada, WLSM mostrou-se mais apropriado que OLSM. Os diferentes comportamentos apontam para a necessidade de uma escolha sensata do modelo mais adequado para expressar a curva analítica e assegurar a confiabilidade do método utilizado.pt_BR
dc.description.abstractenAnalytical methods require adequate curve adjusting models to express reliability. The ordinary or weighted least squares methods (OLSM or WLSM, respectively) were used to determine the most adequate mathematical model for the analytical curve, beginning from the simplest method (linear) to quadratic. These models were evaluated with respect to normality and homoscedasticity of the residues. Analytical curves were built by injection of 1, 5, 10, 15 and 20 L of simvastatin at 40 μg mL–1 (40, 200, 400, 600 and 800 ng) or of 10 L of simvastatin at 4, 20, 40, 60 and 80 μg mL–1, employing high-performance liquid chromatography with photo-diode array detection (238 nm). The best-adjusted models were the linear and the quadratic, when observed in terms of the dataset masses and concentrations, respectively. In the considered range, WLSM was more appropriate than OLSM. The different behavior indicated the need for careful selection of the most adequate model to express the analytical curve and the need for assuring the reliability of the used method.
dc.identifier.citationMARINHO, F. D. M.; REIS, I. A.; SOARES, C. D. V. Construction of analytical curve fit models for simvastatin using ordinary and weighted least squares methods. Journal of the Brazilian Chemical Society, v. 24, p. 1469-1477, 2013. Disponível em: <http://www.scielo.br/pdf/jbchs/v24n9/v24n9a11.pdf>. Acesso em: 22 mai. 2015.pt_BR
dc.identifier.doihttp://dx.doi.org/10.5935/0103-5053.20130187
dc.identifier.issn1678-4790
dc.identifier.urihttp://www.repositorio.ufop.br/handle/123456789/5527
dc.language.isopt_BRpt_BR
dc.rights.licenseTodo o conteúdo do periódico Journal of the Brazilian Chemical Society, exceto onde identificado, está sob uma licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho em qualquer suporte ou formato desde que sejam citados o autor e o licenciante. Fonte: Journal of the Brazilian Chemical Society <http://www.scielo.br/scielo.php?script=sci_serial&pid=0103-5053&lng=en&nrm=iso>. Acesso em: 02 jan. 2017.pt_BR
dc.subjectAnalytical curvespt_BR
dc.subjectLeast squares methodpt_BR
dc.subjectWeighted modelspt_BR
dc.subjectValidationpt_BR
dc.titleConstruction of analytical curve fit models for simvastatin using ordinary and weighted least squares methods.pt_BR
dc.typeArtigo publicado em periodicopt_BR
Arquivos
Pacote Original
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
ARTIGO_ConstructionAnalyticalCurve.pdf
Tamanho:
991.51 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
2.57 KB
Formato:
Item-specific license agreed upon to submission
Descrição: