Avaliação do desempenho térmico do edifício da Escola Municipal do projeto de reassentamento de Bento Rodrigues, Mariana - MG.
dc.contributor.advisor | Gomes, Adriano Pinto | pt_BR |
dc.contributor.advisor | Ribas, Rovadávia Aline de Jesus | pt_BR |
dc.contributor.author | Araújo, Raissa Martins da Silva | |
dc.contributor.referee | Gomes, Adriano Pinto | pt_BR |
dc.contributor.referee | Ribas, Rovadávia Aline de Jesus | pt_BR |
dc.contributor.referee | Lino, Sulamita Fonseca | pt_BR |
dc.contributor.referee | Souza, Henor Artur de | pt_BR |
dc.contributor.referee | Lage, Carmem Miranda | pt_BR |
dc.date.accessioned | 2022-02-24T16:55:18Z | |
dc.date.available | 2022-02-24T16:55:18Z | |
dc.date.issued | 2021 | pt_BR |
dc.description | Programa de Pós-Graduação em Engenharia das Construções. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. | pt_BR |
dc.description.abstract | O estudo do comportamento térmico de edificações tem-se mostrado cada vez mais importante na busca por um ambiente equilibrado termicamente, favorecendo o conforto dos usuários e consequente maior rendimento das atividades a serem desenvolvidas no local. Assim, a busca por um desempenho térmico satisfatório para determinado projeto passa pela escolha correta de materiais e estratégias de construção a fim de se alcançar uma condição térmica adequada, utilizando um sistema eficiente de ventilação, resfriamento ou aquecimento, com um projeto arquitetônico que seja adequado às variáveis climáticas locais. A presente pesquisa tem por objetivo analisar o desempenho térmico do edifício da Escola Municipal de Bento Rodrigues, do Reassentamento de Bento Rodrigues, Mariana, MG, por meio de simulação computacional realizada no software EnergyPlus e, posteriormente, simulação paramétrica do caso crítico utilizando a ferramenta jEPlus. De acordo com a análise realizada, todas as 12 salas de aula presentes na escola atendem, de modo geral, ao critério de desempenho térmico mínimo, exceto a sala de aula 12, que apresenta as maiores temperaturas sob condição padrão. Assim, ela é submetida às análises paramétricas no jEPlus. Nessas simulações, são utilizados os parâmetros originais do projeto e outras opções de composição técnica e de construção, de orientação solar e de taxas de renovação de ar por hora, a fim de se obter os casos mais favoráveis para um desempenho térmico adequado. Para o verão, sob condição padrão e absortância solar α = 0,3, apresentaram o melhor desempenho térmico: o fechamento vertical composto por placa de gesso + lã de rocha + placa cimentícia; a cobertura composta por laje maciça + câmara de ar + telha metálica + poliuretano + telha metálica; o piso cerâmico; a orientação solar voltada 180° para norte e 10 ren/h. E para o inverno, as diferenças em relação ao verão são quanto ao piso, em que a madeira se mostra com desempenho mais satisfatório, e à orientação solar em 0° para sul e 1 ren/h. | pt_BR |
dc.description.abstracten | The study of the thermal behavior of edifications has been become increasingly important in search for a thermically balanced environment, favoring the user’s comfort and consequently increasing the efficiency of the local. Therefore, the search for a satisfactory thermal performance for a specific project depends on the right choice of materials and construction strategies in order to reach a proper thermal condition, using an efficient ventilation, cooling or warming system with an architectural project that suits the local weather changes. This present research’s objective is to analyze the thermal performance of the Escola Municipal Bento Rodrigues building, the Bento Rodrigues Resettlement, in Mariana, Minas Gerais, by computational simulation in EnergyPlus software and, posteriorly, parametric simulation of critical cases using the jEPlus tool. According to the analysis performed, all the 12 school’s classrooms fits the minimum thermal performance requirements, generally, according the standard 15575 (ABNT, 2013), except the Classroom 12, that showed higher temperatures under standard conditions. Then, this classroom was subjected to parametric analysis in jEPlus. In these simulations were used the original parameters of the project and another technical and construction composition options, solar orientation and air renewal rates per hour, in order to obtains more favorable cases to an appropriate thermal performance. For the summer, under standard conditions and solar absorptance α = 0,3, the best thermal performance was shown by: vertical closure compound by plaster board + rock wool + cement board; the roof compound of solid slab + air chamber + polyurethane + metallic roof tile; the ceramic floor; the solar orientation facing 180º to the north and 10ren/h. For the winter, the difference in relation to summer was the floor, where wood has shown a more satisfactory performance, and the solar orientation 0º south and 1ren/h. | pt_BR |
dc.identifier.citation | ARAÚJO, Raissa Martins da Silva. Avaliação do desempenho térmico do edifício da Escola Municipal do projeto de reassentamento de Bento Rodrigues, Mariana - MG. 2021. 118 f. Dissertação (Mestrado Profissional em Engenharia das Construções) - Escola de Minas, Universidade Federal de Ouro Preto, Ouro Preto, 2021. | pt_BR |
dc.identifier.uri | http://www.repositorio.ufop.br/jspui/handle/123456789/14550 | |
dc.language.iso | pt_BR | pt_BR |
dc.rights | aberto | pt_BR |
dc.rights.license | Autorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 14/02/2022 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite a adaptação. | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nd/3.0/us/ | * |
dc.subject | Edificações - conforto térmico | pt_BR |
dc.subject | Espaços coletivos | pt_BR |
dc.subject | Bento Rodrigues - Mariana - MG | pt_BR |
dc.title | Avaliação do desempenho térmico do edifício da Escola Municipal do projeto de reassentamento de Bento Rodrigues, Mariana - MG. | pt_BR |
dc.type | Dissertacao | pt_BR |
Arquivos
Pacote original
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- DISSERTAÇÃO_AvaliaçãoDesempenhoTérmico.pdf
- Tamanho:
- 3.14 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do pacote
1 - 1 de 1
Nenhuma Miniatura Disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: