EM - Escola de Minas
URI permanente desta comunidadehttp://www.hml.repositorio.ufop.br/handle/123456789/6
Notícias
A Escola de Minas de Ouro Preto foi fundada pelo cientista Claude Henri Gorceix e inaugurada em 12 de outubro de 1876.
Navegar
2 resultados
Resultados da Pesquisa
Item Behavior and design formulation of steel CHS with sleeve connections.(2021) Amparo, Lucas Roquete; Oliveira, Matheus Miranda de; Sarmanho, Arlene Maria Cunha; Xavier, Ellen Martins; Alves, Vinicius NicchioStructures with tubular profiles gain space in civil construction due to their excellent response under tension, compression, and torsion. They are widely used in structural trusses, especially in large lengths. The profiles have a limited size due to the manufacturing and transport process. Therefore, there is a need to use some mechanism to perform the joint of profiles and obtain the desired length. This work aims to develop a new type of bar splice in circular hollow section (CHS) connection called sleeve connection, composed of two tubes connected with another smaller diameter tube with bolts arranged in a line (staggered bolts). This research presents an experimental, numerical, and parametric study of sleeve connection in CHS under centric axial tension. A numerical model was developed using the finite element method (FEM) considering sleeve connection with staggered bolts. From the numerical results, it was possible to analyze the connection behavior and failure modes: yielding gross cross-section, fracture through the effective net area, bolt shear failure, bearing failure of the plate, and bolt bending failure. This way, formulations were proposed to predict the sleeve connections' behavior with staggered bolts as a function of the failure modes.Item Experimental analysis of a mechanical shear connector in concrete filled steel tube column.(2017) Ribeiro Neto, Juliano Geraldo; Sarmanho, Arlene Maria CunhaEste trabalho compreende um estudo analítico e experimental do comportamento estrutural de conectores de cisalhamento em pilares mistos, formados por perfis tubulares laminados de seção circular de aço preenchido por concreto simples. Para este estudo foi adotado um conector do tipo parafuso estrutural, a fim de verificar a validade das expressões analíticas constantes na ABNT NBR 16239:2014 [1]. Foi realizada uma série de ensaios experimentais de cisalhamento direto, fixando o diâmetro externo do tubo e variando a espessura, o diâmetro do parafuso, a resistência do concreto e a presença ou não de folga no furo. Da análise dos resultados observa-se que é viável a utilização desse tipo de conector, que as equações existentes para o dimensionamento dos mesmos estão a favor da segurança e podem ser ajustadas para fornecer valores de capacidade resistente mais próximo do experimental.