Navegando por Autor "Cunha, Gabriella Maria Fernandes"
Agora exibindo 1 - 3 de 3
- Resultados por Página
- Opções de Ordenação
Item Methotrexate locally released from poly (caprolactone) implants : inhibition of the inflammatory angiogenesis response in a murine sponge model and the absence of systemic toxicity.(2015) Oliveira, Leandro Gonzaga de; Figueiredo, Letícia Aparecida; Cunha, Gabriella Maria Fernandes; Oliveira, Laser Antônio Machado de; Miranda, Marina Barcelos de; Silva, Gisele Rodrigues da; Moura, Sandra Aparecida Lima deIn this study, the methotrexate (MTX) was incorporated into the poly(-caprolactone) (PCL) to design implants (MTX PCL implants) aiming the local treatment of inflammatory angiogenesis diseases without causing systemic side effects. Sponges were inserted into the subcutaneous tissue of mice as a framework for fibrovascular tissue growth. After 4 days, MTX PCL implants were also introduced, and anti-inflammatory, antiangiogenic, and antifibrogenic activities of the MTX were determined. MTX reduced the vascularization (hemoglobin content), the neutrophil, and monocyte/macrophage infiltration (MPO and NAG activities, respectively), and the collagen deposition in sponges. MTX reduced tumor necrosis factor-_ and IL-6 levels, demonstrating its local antiangiogenic and anti-inflammatory effects. Furthermore, hepatotoxicity, nephrotoxicity, and myelotoxicity, which could be induced by the drug, were evaluated. However, MTX did not promote toxicity to these organs, as the levels of AST and ALT (hepatic markers) and creatinine and urea (renal markers) were not increased, and the complete blood count was not decreased. In conclusion, MTX PCL implants demonstrated to be effective in regulating the components of the inflammatory angiogenesis locally established, and presented an acceptable safety profile. C _ 2015Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci.Item Ocular biocompatibility of dexamethasone acetate loaded poly(ɛcaprolactone) nanofibers.(2019) Silva, Gisele Rodrigues da; Lima, Tadeu Henrique de; Cunha, Gabriella Maria Fernandes; Oréfice, Rodrigo Lambert; Cunha Júnior, Armando da Silva; Zhao, Min; Cohen, Francine BeharElectrospinning technique has been explored to produce nanofibers incorporated with drugs as alternative drug delivery systems for therapeutic purposes in various organs and tissues. Before such systems could potentially be used, their biocompatibility must be evaluated. In this study, dexamethasone acetate-loaded poly(ɛ-caprolactone) nanofibers (DX PCL nanofibers) were developed for targeted delivery in the vitreous cavity in the treatment of retinal diseases. Ocular biocompatibility was tested in vitro and in vivo. DX PCL nanofibers were characterized by scanning electron microscopy (SEM) and Fourier Transform InfraRed spectroscopy (FTIR) and the in vitro drug release from nanofibers was evaluated. The in vitro biocompatibility of DX PCL nanofibers was tested on both ARPE-19 and MIO-M1 cells using the cytotoxicity (MTT) test by morphological studies based on staining of the actin fibers in ARPE-19 cells and GFAP in MIO-M1 cells. The in vivo biocompatibility of DX PCL nanofibers was investigated after intravitreous injection in the rat eye, using spectral domain Optical Coherence Tomography (OCT) imaging of the retina. SEM results indicated that nanometric fibers were interconnected in a complex network, and that they were composed of polymer. FTIR showed that polymer and drug did not chemically interact after the application of the electrospinning technique. PCL nanofibers provided controlled DX release for 10 days. DX PCL nanofibers were not cytotoxic to the ocular cells, allowing for the preservation of actin fibers and GFAP in the cytoplasm of ARPE-19 and MIO-M1 cells, respectively, which are biomarkers of these ocular cell populations. DX PCL nanofibers did not affect the retinal and choroidal structures, and they did not induce abnormalities, hemorrhages, or retinal detachment, suggesting that the nanofibers were well tolerated. In eyes receiving DX PCL nanofibers, SD-OCT images were corroborated with histological analysis of neuroretina and choroid, which are ocular tissues that are extremely sensitive to toxic agents. Finally, the preservation of cone and rod photoreceptors indicated the light sensitivity of the animals. In conclusion, DX PCL nanofibers exhibited ocular biocompatibility and safety in the rodent eye and allow the release of dexamethasone. Further studies are required to appreciate the potential of these new drug delivery systems for the treatment of retinal diseases.Item Ocular safety of intravitreal clindamycin hydrochloride released by PLGA implants.(2017) Cunha, Gabriella Maria Fernandes; Fialho, Sílvia Ligório; Silva, Gisele Rodrigues da; Cunha Júnior, Armando da Silva; Zhao, Min; Cohen, Francine BeharBackground Drug ocular toxicity is a field that requires attention. Clindamycin has been injected intravitreally to treat ocular toxoplasmosis, the most common cause of eye posterior segment infection worldwide. However, little is known about the toxicity of clindamycin to ocular tissues. We have previously showed non intraocular toxicity in rabbit eyes of poly(lactic-co-glycolic acid) (PLGA) implants containing clindamycin hydrochloride (CLH) using only clinical macroscotopic observation. In this study, we investigated the in vivo biocompatibility of CLH-PLGA implants at microscotopic, cellular and molecular levels. Methods Morphology of ARPE-19 and MIO-M1 human retinal cell lines was examined after 72 h exposure to CLH-PLGA implant. Drug delivery system was also implanted in the vitreous of rat eyes, retinal morphology was evaluated in vivo and ex vivo. Morphology of photoreceptors and inflammation was assessed using immunofluorescence and real-time PCR. Results After 72 h incubation with CLH-PLGA implant, ARPE-19 and MIO-M1 cells preserved the actin filament network and cell morphology. Rat retinas displayed normal lamination structure at 30 days after CLH-PLGA implantation. There was no apoptotic cell and no loss in neuron cells. Cones and rods maintained their normal structure. Microglia/macrophages remained inactive. CLH-PLGA implantation did not induce gene expression of cytokines (IL-1β, TNF-α, IL-6), VEGF, and iNOS at day 30. Conclusion These results demonstrated the safety of the implant and highlight this device as a therapeutic alternative for the treatment of ocular toxoplasmosis.